• Original Siemens Brand Mechanical Loa24.171b27 Gas Burner Combustion Program Controllersequence Controller for Burner Parts
  • Original Siemens Brand Mechanical Loa24.171b27 Gas Burner Combustion Program Controllersequence Controller for Burner Parts
  • Original Siemens Brand Mechanical Loa24.171b27 Gas Burner Combustion Program Controllersequence Controller for Burner Parts
  • Original Siemens Brand Mechanical Loa24.171b27 Gas Burner Combustion Program Controllersequence Controller for Burner Parts
  • Original Siemens Brand Mechanical Loa24.171b27 Gas Burner Combustion Program Controllersequence Controller for Burner Parts
  • Original Siemens Brand Mechanical Loa24.171b27 Gas Burner Combustion Program Controllersequence Controller for Burner Parts

Original Siemens Brand Mechanical Loa24.171b27 Gas Burner Combustion Program Controllersequence Controller for Burner Parts

Usage: Hydrogen, Nitrogen
Noise Level: Low
Machine Size: Small
Condition: New
Certification: ISO, CE
Name: Burner Controller
Samples:
US$ 98/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
  • Overview
  • Product Description
  • Detailed Photos
  • Recommend Products
Overview

Basic Info.

Model NO.
LOA24.171B27
Model
Loa24.171b27
Brand
Siemens
Power Supply
220-240V 50/60 Hz.
Power Consumption
Approx. AC 3.5 Va
Ambient Temperature
-20...+60 °c
Weight
Less 1kg
Color
Black
Primary Fuse (External)
Max. 10 a (Slow)
Humidity
< 95 % R.H
After Warranty Service
Video Technical Support
Application/Usage
Gas Burners Industrial Accessories
Transport Package
Carton
Specification
11*8*7cm
Trademark
Siemens
Origin
Germany
HS Code
8302600000
Production Capacity
1000

Product Description

Original Siemens Brand Mechanical  LOA24.171B27 Gas Burner Combustion Program ControllerSequence Controller For Burner Parts

Product Description

Use, features:
Use:The LOA... are used for the startup, supervision and control of 1- or 2-stage forced draft oil burners in intermittent operation.
Yellow-burning flames are supervised with photoresistive detectors QRB..., blueburning flames with blue-flame detectors QRC...
General features: - Forced draft oil burners conforming to EN 267
- Oil atomization burners in monoblock design conforming to EN 230: 1991
- Undervoltage detection
- Bridging contact for oil preheater (not with LOA28.173A27)
General features - Special versions including models for incinerator plants and flash-steam generators
- LOA36... with color display of flame intensity and operating

PRODUCT SPECIFICATIONS
item
value
Condition
New
Warranty
1.5 years
Applicable Industries
Manufacturing Plant, Food & Beverage Factory, Farms, Restaurant, Construction works , Energy & Mining, Advertising Company
Weight (KG)
Less 1kg
Showroom Location
None
Video outgoing-inspection
Provided
Machinery Test Report
Provided
Place of Origin
Germany
Brand Name
Siemens
Type
Gas Burner
Product name
 LOA24.171B27 Gas Burner Combustion Program ControllerSequence Controller
Brand
Siemens
Model
LOA24.171B27
Color
Black
Power supply
220-240V 50/60 Hz.
Power consumption approx. AC 3.5 VA
Ambient Temperature
-20...+60 °C
Humidity
< 95 % r.h.
Degree of protection  IP 40, with the exception of  the connection area
Application/Usage
Gas Burners Industrial Accessories

Detailed Photos

Original Siemens Brand Mechanical  LOA24.171B27 Gas Burner Combustion Program ControllerSequence Controller For Burner Parts
Original Siemens Brand Mechanical Loa24.171b27 Gas Burner Combustion Program Controllersequence Controller for Burner Parts
Installation notes:
1.Always run high-voltage ignition cables separately while observing the greatest
possible distance to the unit and to other cables
2.Do not mix up live and neutral conductors
Install switches, fuses, earthing, etc., in compliance with local regulations
3.Ensure that the maximum permissible amperages will not be exceeded (see Tech
nical data)

 
 
Original Siemens Brand Mechanical Loa24.171b27 Gas Burner Combustion Program Controllersequence Controller for Burner Parts

Electrical connection of flame detectors:

It is important to achieve practically disturbance- and loss-free signal transmission:
1.Never run the detector cable together with other cables
- Line capacitance reduces the magnitude of the flame signal
- Use a separate cable
2. Observe the permissible lengths of the flame detector cables (see Data Sheets
N7714 (QRB...) and N7716 (QRC...))
3.Earth the burner in compliance with the relevant regulations; earthing the boiler
alone does not suffice

 

Original Siemens Brand Mechanical Loa24.171b27 Gas Burner Combustion Program Controllersequence Controller for Burner Parts
Warning notes:
To avoid injury to persons, damage to property or the environment, the following warning notes must be observed!
Do not open, interfere with or modify the unit!
1. All activities (mounting, installation and service work, etc.) must be performed by qualified staff
2.Before making any wiring changes in the connection area, completely isolate the plant from mains supply (all-polar disconnection). Ensure that the plant cannot be inadvertently switched on again and that it is indeed dead. If not observed, there is a risk of electric shock hazard
3. Ensure protection against electric shock hazard by providing adequate protection for the burner control's connection terminals. If not observed, there will be a risk of electric shock
4. Each time work has been carried out (mounting, installation, service work, etc.), check to ensure that wiring is in an orderly state and make the safety checks as indicated in Commissioning notes above
5.Press the lockout reset button / operating button only manually (applying a force of no more than 60 N), without using any tools or pointed objects. If not observed, the safety functions are no longer ensured and there will be a risk of electric shock
6.Fall or shock can adversely affect the safety functions. Such units must not be put into operation, even if they do not exhibit any damage. If not observed, the safety functions are no longer ensured and there will be a risk of electric shock
Mounting notes Ensure that the relevant national safety regulations are complied with.


Original Siemens Brand Mechanical Loa24.171b27 Gas Burner Combustion Program Controllersequence Controller for Burner Parts

 

Recommend Products

 

Original Siemens Brand Mechanical Loa24.171b27 Gas Burner Combustion Program Controllersequence Controller for Burner Parts
Original Siemens Brand Mechanical Loa24.171b27 Gas Burner Combustion Program Controllersequence Controller for Burner Parts
Original Siemens Brand Mechanical Loa24.171b27 Gas Burner Combustion Program Controllersequence Controller for Burner Parts
 
Original Siemens Brand Mechanical Loa24.171b27 Gas Burner Combustion Program Controllersequence Controller for Burner Parts
Original Siemens Brand Mechanical Loa24.171b27 Gas Burner Combustion Program Controllersequence Controller for Burner Parts
Original Siemens Brand Mechanical Loa24.171b27 Gas Burner Combustion Program Controllersequence Controller for Burner Parts

 

Original Siemens Brand Mechanical  LOA24.171B27 Gas Burner Combustion Program ControllerSequence Controller For Burner Parts
Original Siemens Brand Mechanical Loa24.171b27 Gas Burner Combustion Program Controllersequence Controller for Burner PartsOriginal Siemens Brand Mechanical Loa24.171b27 Gas Burner Combustion Program Controllersequence Controller for Burner Parts

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
40
Year of Establishment
2009-08-20