  • Compliance with Safety Regulations: Designed and built in compliance with current regulations and directives for safety.
  • CE and ISO Certification: Product holds CE and ISO certifications ensuring quality and safety standards.
  • Low Noise Operation: Engineered for low noise levels suitable for industrial environments.
  • Adjustable Combustion Head: Combustion heads with different lengths available to fit various boiler requirements.
  • Complete Burner Package: Supplied with gas train flange, gaskets, screws, thermal insulation, and instruction manual.
  • Video Technical Support: Post-warranty service includes video technical support for troubleshooting.
  • OEM and ODM Services: Manufacturer offers both OEM and ODM services for customized production needs.
  • Fast Delivery Time: Standard delivery time ranges from 2 to 15 days depending on order specifics.

Product Images of RS130/M Tc Industrial Furnace High Power Gas Burner

RS130/M Tc Industrial Furnace High Power Gas Burner pictures & photos
RS130/M Tc Industrial Furnace High Power Gas Burner
RS130/M Tc Industrial Furnace High Power Gas Burner pictures & photos
RS130/M Tc Industrial Furnace High Power Gas Burner
RS130/M Tc Industrial Furnace High Power Gas Burner pictures & photos
RS130/M Tc Industrial Furnace High Power Gas Burner
RS130/M Tc Industrial Furnace High Power Gas Burner pictures & photos
RS130/M Tc Industrial Furnace High Power Gas Burner
RS130/M Tc Industrial Furnace High Power Gas Burner pictures & photos
RS130/M Tc Industrial Furnace High Power Gas Burner
RS130/M Tc Industrial Furnace High Power Gas Burner pictures & photos
RS130/M Tc Industrial Furnace High Power Gas Burner
  • RS130/M Tc Industrial Furnace High Power Gas Burner
    RS130/M Tc Industrial Furnace High Power Gas Burner
  • RS130/M Tc Industrial Furnace High Power Gas Burner
    RS130/M Tc Industrial Furnace High Power Gas Burner
  • RS130/M Tc Industrial Furnace High Power Gas Burner
    RS130/M Tc Industrial Furnace High Power Gas Burner
  • RS130/M Tc Industrial Furnace High Power Gas Burner
    RS130/M Tc Industrial Furnace High Power Gas Burner
  • RS130/M Tc Industrial Furnace High Power Gas Burner
    RS130/M Tc Industrial Furnace High Power Gas Burner
  • RS130/M Tc Industrial Furnace High Power Gas Burner
    RS130/M Tc Industrial Furnace High Power Gas Burner

Find Similar Products

Product Description

   RS130/M  Burner For Heating industry

The burners have been designed and built in compliance with current regulations and directives, applying the known technical rules of safety and envisaging all the potential danger situations. It is necessary, however, to bear in mind that the imprudent and clumsy use of the equipment may lead to situations of death risk for the user or third parties, as well as the damaging of the burner or other items. Inattention, thoughtlessness and excessive confidence often cause accidents; the same applies to tiredness and sleepiness.

It is a good idea to remember the following:
³ The burner must only be used as expressly described. Any other use should be considered improper and therefore dangerous.
In particular:
it can be applied to boilers operating with water, steam, diathermic oil, and to other users expressly named by the
manufacturer; the type and pressure of the fuel, the voltage and frequency of the electrical power supply, the minimum and maximum deliveries for which the burner has been regulated, the pressurisation of the combustion chamber, the dimensions of the combustion chamber and the room temperature must all be within the values indicated in the instruction manual.
³ Modification of the burner to alter its performance and destinations is not allowed.
³ The burner must be used in exemplary technical safety conditions. Any disturbances that could compromise safety must be quickly eliminated.
³ Opening or tampering with the burner components is not allowed, apart from the parts requiring maintenance.
³ Only those parts envisaged by the manufacturer can be replaced
Model
  RS130/M
  Name    RS130/M  Burner
Usage
Gas Industrial burner
 
RS130/M Tc Industrial Furnace High Power Gas BurnerRS130/M Tc Industrial Furnace High Power Gas Burner
Describle of Burner
Burner Head
RS series burners can choose combustion heads of different lengths according to different needs. The selection is based on the thickness of the front plate of the boiler and different types of boilers. Depending on the heat user, check that the combustion head is correctly installed in the combustion chamber. Flange-mounted screws can be easily adjusted to adjust the internal position of the burner head for full the maximum output of the burner.
RS130/M Tc Industrial Furnace High Power Gas Burner
The user is the person, body or company that has acquired the machine and intends to use it for the specific purpose. He is responsible for the machine and for the training of the people working around it.
The user:
³ undertakes to entrust the machine exclusively to suitably trained and qualified personnel;
³ must take all the measures necessary to prevent unauthorised people gaining access to the machine;
³ undertakes to inform his personnel in a suitable way about the application and observance of the safety instructions.With that aim, he undertakes to ensure that everyone knows the use and safety instructions for his own duties;
³ must inform the Manufacturer if faults or malfunctioning of the accident prevention systems are noticed, along with
any presumed danger situation.
³ Personnel must always use the personal protective equipment envisaged by legislation and follow the indications given in this manual.
³ Personnel must follow all the danger and caution indications shown on the machine.
³ Personnel must not carry out, on their own initiative, operations or interventions that are not within their province.
³ Personnel must inform their superiors of every problem or dangerous situation that may arise.
³ The assembly of parts of other makes or any modifications can alter the characteristics of the machine and hence
compromise operating safety. The manufacturer therefore declines any and every responsibility for any damage that
may be caused by the use of non-original parts.
RS130/M Tc Industrial Furnace High Power Gas Burner
(1) Reference conditions: Ambient temperature 20°C - Gas temperature 15°C - Barometric pressure 1013 mbar - Altitude 0m above sea
level.
(2) Gas pressure on the pipe coupling test point 16) (Fig. 5) with zero pressure in the combustion chamber and at maximum burner
output.
(3) Sound pressure measured in manufacturer's combustion laboratory, with burner operating on test boiler and at maximum output.
RS130/M Tc Industrial Furnace High Power Gas Burner
1 Combustion head
2 Ignition electrode
3 Screw for combustion head adjustment
4 Maximum gas pressure switch
5 Servomotor controlling the gas butterfly valve and the air damper valve (by means of an adjustable profile cam
mechanism). When the burner is not operating the air gate valve is fully closed in order to reduce heat dispersion from the boiler due to the flue draught which draws air from the fan suction inlet.
6 Plug-socket on ionisation probe cable
7 Extensions for slide bars 15)
8 Motor contact maker and thermal relay with reset button
9 Power switch for: automatic - manual - off Button for: power increase - power reduction
10 Terminal board for electrical wiring
11 Cable grommets for electrical wiring (to be carried out by the installer)
12 Control box with lockout pilot light and lockout reset button
13 Flame inspection window
14 Air pressure switch (differential operating type)
15 Slide bars for opening the burner and inspecting the combustion head
16 Gas pressure test point and head fixing screw
17 Air pressure socket
18 Flame sensor probe
19 Air damper
20 Fan air inlet
21 Screws to secure fan to pipe coupling
22 Gas input pipe
23 Gas butterfly valve
24 Boiler fixing flange
25 Flame stability disc
26 Bracket for application of output power regulator RWF40
Burner equipment:
The burner is supplied complete with:
³ Gas train flange
³ Flange gasket
³ 4 screws to fix the M8x25 flange
³ Thermal insulation screen
³ Extensions 7) per guides 15): only TL versions
³ 4 screws to fix the M12x35 burner flange to the boiler
³ Instruction manual
³ Spare parts list

RS130/M Tc Industrial Furnace High Power Gas Burner
Installation:
Securing the burner to the boiler
Before fixing the burner to the boiler, check from the opening of the blast tube that the probe and the electrode are
correctly positioned, as in Fig. 12.
If, in the previous check, the position of the probe or electrode was not correct, remove the screw 1)(Fig. 13), extract
the inner part 2)(Fig. 13) of the head, and adjust them.
Do not rotate the probe: leave it as in Fig. 12 since if it is
located too close to the ignition electrode, the control box
amplifier may be damaged.
Separate the combustion head from the rest of the burner, Fig. 11. To do this, proceed as follows:
- loosen the 4 screws 3) and remove the hood 1);
- disengage the articulated coupling 7) from the graduated sector 8);
- remove screws 2) from the two slide bars 5);
- remove the 2 screws 4) and pull the burner back on slide bars 5) by about 100 mm;
- disconnect the probe and electrode cables, then slide off the burner completely from the slide bars. Once this operation has been carried out, fix the flange 11)(Fig. 11) to the boiler plate, interposing the insulating gasket 9)(Fig. 11) supplied.
Use the 4 screws supplied, with a tightening torque of 35 - 40 Nm, after protecting their thread with anti-seize prod
ucts.
The seal between burner and boiler must be airtight. After the start-up (see Ch. 5.3), check there is no leakage of flue
gases into the external environment.
RS130/M Tc Industrial Furnace High Power Gas Burner

Recommend Products

RS130/M Tc Industrial Furnace High Power Gas Burner
RS130/M Tc Industrial Furnace High Power Gas Burner
RS130/M Tc Industrial Furnace High Power Gas Burner

 

RS130/M Tc Industrial Furnace High Power Gas BurnerRS130/M Tc Industrial Furnace High Power Gas Burner

About the Supplier

This supplier has been audited by BV. Verify the report on the official BV website with ID "MIC-ASI262546". Items marked "verified" are certified.

Watch Video
Watch Video
Guangdong JATE Burner Co.,Ltd
Guangdong JATE Burner Co.,Ltd
Guangdong JATE Burner Co.,Ltd
Guangdong JATE Burner Co.,Ltd
Guangdong JATE Burner Co.,Ltd
Guangdong JATE Burner Co.,Ltd
Guangdong JATE Burner Co.,Ltd
Guangdong JATE Burner Co.,Ltd

About Our Factory & Business Background

verified Business Type
Manufacturer/Factory & Trading Company
Address
No. 101, Buiding C16, Zone C, Gaoshengxihuzhigu, Hongling Third Road, Shuikou Street, Huizhou, Guangdong
verified Plant Area
5567 square meters
verified Number of Employees
47
verified Registered Capital
10,000,000 RMB
verified Terms of Payment
LC, T/T, D/P, Western Union, PayPal, Small-amount payment
verified International Commercial Terms(Incoterms)
CIF, FOB, CFR, EXW
verified Average Lead Time
Peak Season Lead Time: within 15 workdays, one month
Off Season Lead Time: within 15 workdays, one month
verified Nearest Port
Shenzhen Port, Guangzhou Port
verified Minimum Order Quantity
1 PCS
verified Supply Chain Partners
30

Our Production Capability & Technical Expertise

verified Main Products
Industrial Burner, Combustion Chamber, Gasifier, Infrared Gas Burner, Oil Pump, Burner Controller, Flame Detector, Damper Actuator, Regulator, Butterfly Valve
verified Production Lines
2
verified Production Machines
Bending Machine, Cutting Machine, Laser Cutting Machine, Testing Machine, Welding Machine
verified QA/QC inspectors
2 people
verified Inspection Type for Finished Products
100% inspection(Visual inspection & Function inspection)
verified Inspection Method for Finished Products
Have instructions and uniformly followed
verified Customization Options
Customization from Samples, Customization from Designs, Full Customization, Minor Customization, Flexible customization
verified ODM Service Available
Yes
verified OEM Service Available
Yes
verified R&D Engineers
4 people
verified Traceability of Raw Materials
Yes
verified Own Brand
Yes

Our Industry Experience & Global Business Record

verified Year of Establishment
2024-04-15
verified Export Year
N/A
verified Main Markets
Domestic
verified Repeat Buyers Choice
30%~50%
verified Number of Foreign Trading Staff
5
verified Overseas Agent/Branch
No
verified New Products Launched in Last year
Yes

Our Certifications, Standards & Industry Recognition

verified Cooperated with Fortune 500
Yes

FAQ

What certifications does the RS130/M Burner have?
The burner is certified with CE and ISO standards.
Can the combustion head be customized?
Yes, RS series burners can choose combustion heads of different lengths according to different needs based on boiler thickness.
What is the delivery time for this product?
The delivery time is typically between 2 to 15 days.
Is the product new or used?
The condition of the RS130/M Burner is New.
What fuels can this burner use?
The burner is designed for usage with Hydrogen, Nitrogen, and Natural Gas (Ng).
What payment terms are accepted?
Accepted payment terms include LC, T/T, D/P, PayPal, Western Union, and Small-amount payment.
Does the manufacturer offer OEM or ODM services?
Yes, both OEM and ODM services are available.
What is included in the burner package?
The package includes a gas train flange, flange gasket, screws, thermal insulation screen, extensions, instruction manual, and spare parts list.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now