Usage: Hydrogen, Nitrogen, Ng and LPG
Purpose: Control Gas
Parts: Burner Controller
Application Fields: Industrial Gas Burner
Noise Level: Low
Machine Size: Medium
Samples:
US$ 13/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
  • Overview
  • Product Description
  • Detailed Photos
  • Recommend Products
Overview

Basic Info.

Model NO.
LMO24.111C2
Condition
New
Certification
ISO, CE
Name
Burner Controller
Model
Lmo24.111c2
Brand
Jate
Power Supply
230V 50/60 Hz.
Weight
Less 1kg
Tsamax
10s
Color
Black
After Warranty Service
Video Technical Support
Application/Usage
Gas Burners Industrial Accessories
Shipping Term
DHL/UPS/FedEx/TNT
Transport Package
Carton
Specification
11*8*7cm
Trademark
JATE
Origin
China
HS Code
8302600000
Production Capacity
1000

Product Description

JATE Brand Electronic Sequence LMO24.111C2 Gas Combustion Controller Burner Controller Accessories

Product Description

Application:
LME...for monitoring and control of single-stage or double-stage gas burners during start-up and intermittent operation. flame monitoring Pass ionization bar or flame detector QRA and auxiliary equipment AGQ3 or use blue flame detector QRC. according to the shell Dimensions, LME... Same burner controller as LGB and LMG

PRODUCT SPECIFICATIONS
item
value
Condition
New
Warranty
1.5 years
Applicable Industries
Manufacturing Plant, Food & Beverage Factory, Farms, Restaurant, Construction works , Energy & Mining, Advertising Company
Weight (KG)
Less 1kg
Showroom Location
None
Video outgoing-inspection
Provided
Machinery Test Report
Provided
Place of Origin
China
Brand Name
JATE
Type
Gas Burner
Product name
LMO24.111C2 Gas Combustion Controller Burner Controller
Brand
JATE
Model
LMO24.111C2
Color
Black
Power supply
230V 50/60 Hz.
TSAmax 10s
Shipping Term  DHL/UPS/Fedex/TNT
Application/Usage
Gas Burners Industrial Accessories

Detailed Photos

JATE Brand Electronic Sequence LMO24.111C2 Gas Combustion Controller Burner Controller Accessories
Jate Brand Electronic Sequence Lmo24.111c2 Gas Combustion Controller Burner Controller Accessories Control Relay
Use, features:
Use: The LOA... are used for the startup, supervision and control of 1- or 2-stage forced draft oil burners in intermittent operation.
Yellow-burning flames are supervised with photoresistive detectors QRB..., blueburning flames with blue-flame detectors QRC...
General features: - Forced draft oil burners conforming to EN 267
- Oil atomization burners in monoblock design conforming to EN 230: 1991
- Undervoltage detection
- Bridging contact for oil preheater (not with LOA28.173A27)
General features - Special versions including models for incinerator plants and flash-steam generators
- LOA36... with color display of flame intensity and operating

 
 
Jate Brand Electronic Sequence Lmo24.111c2 Gas Combustion Controller Burner Controller Accessories Control Relay
Installation notes:
1.Always run high-voltage ignition cables separately while observing the greatest possible distance to the unit and to other cables
2.Do not mix up live and neutral conductors
3.Install switches, fuses, earthing, etc., in compliance with local regulations
4.Ensure that the maximum permissible amperages will not be exceeded (see Technical data)

 

Jate Brand Electronic Sequence Lmo24.111c2 Gas Combustion Controller Burner Controller Accessories Control Relay
Electrical installation of flame detectors:
To exclude interference, it is important to avoid losses in signal transmission:
1.Do not install the detector wires together with other wires - Line capacitance reduces the level of the flame signal - Use a separate cable
2.Check the maximum permissible length of the detector wiring (refer to the «Technical Manual»)
3.The ionization bar is not protected against the risk of electric shock
4.Locate and confirm the location of the ignition electrode and ionization probe so that the ignition spark does not pass over the ionization rod (danger of electrical overload) and checks that affect ionization
5.Insulation resistance - Minimum resistance between ion bar and ground is 50 M- Contaminated detector mounts reduce insulation resistance, thereby supporting creep currents The wiring of the burner should comply with the relevant regulations; grounding the boiler alone is not sufficient



Jate Brand Electronic Sequence Lmo24.111c2 Gas Combustion Controller Burner Controller Accessories Control Relay

 

Recommend Products

 

Jate Brand Electronic Sequence Lmo24.111c2 Gas Combustion Controller Burner Controller Accessories Control Relay
Jate Brand Electronic Sequence Lmo24.111c2 Gas Combustion Controller Burner Controller Accessories Control Relay
Jate Brand Electronic Sequence Lmo24.111c2 Gas Combustion Controller Burner Controller Accessories Control Relay
 
Jate Brand Electronic Sequence Lmo24.111c2 Gas Combustion Controller Burner Controller Accessories Control Relay
Jate Brand Electronic Sequence Lmo24.111c2 Gas Combustion Controller Burner Controller Accessories Control Relay
Jate Brand Electronic Sequence Lmo24.111c2 Gas Combustion Controller Burner Controller Accessories Control Relay

 

JATE Brand Electronic Sequence LMO24.111C2 Gas Combustion Controller Burner Controller Accessories
Jate Brand Electronic Sequence Lmo24.111c2 Gas Combustion Controller Burner Controller Accessories Control RelayJate Brand Electronic Sequence Lmo24.111c2 Gas Combustion Controller Burner Controller Accessories Control Relay

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now