• Riello RS130/M Tc Industrial Natural Gas Burner for Heating
  • Riello RS130/M Tc Industrial Natural Gas Burner for Heating
  • Riello RS130/M Tc Industrial Natural Gas Burner for Heating
  • Riello RS130/M Tc Industrial Natural Gas Burner for Heating
  • Riello RS130/M Tc Industrial Natural Gas Burner for Heating
  • Riello RS130/M Tc Industrial Natural Gas Burner for Heating

Riello RS130/M Tc Industrial Natural Gas Burner for Heating

Usage: Hydrogen, Nitrogen, Ng
Purpose: Heating
Parts: Valve
Application Fields: Industrial Gas Burner
Noise Level: Low
Machine Size: Medium
Samples:
US$ 4350/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
  • Overview
  • Recommend Products
Overview

Basic Info.

Model NO.
RS150/M
Condition
New
Certification
ISO, CE
Model
RS150/M
Brand
Riello
Name
Riello RS130/M Burner
Environment Temperature
Normal
Customize
No
Deliver Time
2-15days
Term of Payment
EXW/Fob
Color
Red
Use
Gas Industrial Burner
After Warranty Service
Video Technical Support
Transport Package
Wooden Box
Specification
141*70*66CM
Trademark
Riello
Origin
Italy
HS Code
8416100000
Production Capacity
100

Product Description

 Riello RS150/M  Burner For Heating industry

The burners have been designed and built in compliance with current regulations and directives, applying the known technical rules of safety and envisaging all the potential danger situations. It is necessary, however, to bear in mind that the imprudent and clumsy use of the equipment may lead to situations of death risk for the user or third parties, as well as the damaging of the burner or other items. Inattention, thoughtlessness and excessive confidence often cause accidents; the same applies to tiredness and sleepiness.

It is a good idea to remember the following:
³ The burner must only be used as expressly described. Any other use should be considered improper and therefore dangerous.
In particular:
it can be applied to boilers operating with water, steam, diathermic oil, and to other users expressly named by the
manufacturer; the type and pressure of the fuel, the voltage and frequency of the electrical power supply, the minimum and maximum deliveries for which the burner has been regulated, the pressurisation of the combustion chamber, the dimensions of the combustion chamber and the room temperature must all be within the values indicated in the instruction manual.
³ Modification of the burner to alter its performance and destinations is not allowed.
³ The burner must be used in exemplary technical safety conditions. Any disturbances that could compromise safety must be quickly eliminated.
³ Opening or tampering with the burner components is not allowed, apart from the parts requiring maintenance.
³ Only those parts envisaged by the manufacturer can be replaced
Model
  RS150/M
Brand
  Riello
  Name   Riello RS150/M  Burner
Usage
Gas Industrial burner
 
Riello RS130/M Tc Industrial Natural Gas Burner for HeatingRiello RS130/M Tc Industrial Natural Gas Burner for Heating
Describle of Burner
Burner Head
RS series burners can choose combustion heads of different lengths according to different needs. The selection is based on the thickness of the front plate of the boiler and different types of boilers. Depending on the heat user, check that the combustion head is correctly installed in the combustion chamber. Flange-mounted screws can be easily adjusted to adjust the internal position of the burner head for full the maximum output of the burner.
Riello RS130/M Tc Industrial Natural Gas Burner for Heating
The user is the person, body or company that has acquired the machine and intends to use it for the specific purpose. He is responsible for the machine and for the training of the people working around it.
The user:
³ undertakes to entrust the machine exclusively to suitably trained and qualified personnel;
³ must take all the measures necessary to prevent unauthorised people gaining access to the machine;
³ undertakes to inform his personnel in a suitable way about the application and observance of the safety instructions.With that aim, he undertakes to ensure that everyone knows the use and safety instructions for his own duties;
³ must inform the Manufacturer if faults or malfunctioning of the accident prevention systems are noticed, along with
any presumed danger situation.
³ Personnel must always use the personal protective equipment envisaged by legislation and follow the indications given in this manual.
³ Personnel must follow all the danger and caution indications shown on the machine.
³ Personnel must not carry out, on their own initiative, operations or interventions that are not within their province.
³ Personnel must inform their superiors of every problem or dangerous situation that may arise.
³ The assembly of parts of other makes or any modifications can alter the characteristics of the machine and hence
compromise operating safety. The manufacturer therefore declines any and every responsibility for any damage that
may be caused by the use of non-original parts.
Riello RS130/M Tc Industrial Natural Gas Burner for Heating
(1) Reference conditions: Ambient temperature 20°C - Gas temperature 15°C - Barometric pressure 1013 mbar - Altitude 0m above sea
level.
(2) Gas pressure on the pipe coupling test point 16) (Fig. 5) with zero pressure in the combustion chamber and at maximum burner
output.
(3) Sound pressure measured in manufacturer's combustion laboratory, with burner operating on test boiler and at maximum output.
Riello RS130/M Tc Industrial Natural Gas Burner for Heating
1 Combustion head
2 Ignition electrode
3 Screw for combustion head adjustment
4 Maximum gas pressure switch
5 Servomotor controlling the gas butterfly valve and the air damper valve (by means of an adjustable profile cam
mechanism). When the burner is not operating the air gate valve is fully closed in order to reduce heat dispersion from the boiler due to the flue draught which draws air from the fan suction inlet.
6 Plug-socket on ionisation probe cable
7 Extensions for slide bars 15)
8 Motor contact maker and thermal relay with reset button
9 Power switch for: automatic - manual - off Button for: power increase - power reduction
10 Terminal board for electrical wiring
11 Cable grommets for electrical wiring (to be carried out by the installer)
12 Control box with lockout pilot light and lockout reset button
13 Flame inspection window
14 Air pressure switch (differential operating type)
15 Slide bars for opening the burner and inspecting the combustion head
16 Gas pressure test point and head fixing screw
17 Air pressure socket
18 Flame sensor probe
19 Air damper
20 Fan air inlet
21 Screws to secure fan to pipe coupling
22 Gas input pipe
23 Gas butterfly valve
24 Boiler fixing flange
25 Flame stability disc
26 Bracket for application of output power regulator RWF40
Burner equipment:
The burner is supplied complete with:
³ Gas train flange
³ Flange gasket
³ 4 screws to fix the M8x25 flange
³ Thermal insulation screen
³ Extensions 7) per guides 15): only TL versions
³ 4 screws to fix the M12x35 burner flange to the boiler
³ Instruction manual
³ Spare parts list

Riello RS130/M Tc Industrial Natural Gas Burner for Heating
Installation:
Securing the burner to the boiler
Before fixing the burner to the boiler, check from the opening of the blast tube that the probe and the electrode are
correctly positioned, as in Fig. 12.
If, in the previous check, the position of the probe or electrode was not correct, remove the screw 1)(Fig. 13), extract
the inner part 2)(Fig. 13) of the head, and adjust them.
Do not rotate the probe: leave it as in Fig. 12 since if it is
located too close to the ignition electrode, the control box
amplifier may be damaged.
Separate the combustion head from the rest of the burner, Fig. 11. To do this, proceed as follows:
- loosen the 4 screws 3) and remove the hood 1);
- disengage the articulated coupling 7) from the graduated sector 8);
- remove screws 2) from the two slide bars 5);
- remove the 2 screws 4) and pull the burner back on slide bars 5) by about 100 mm;
- disconnect the probe and electrode cables, then slide off the burner completely from the slide bars. Once this operation has been carried out, fix the flange 11)(Fig. 11) to the boiler plate, interposing the insulating gasket 9)(Fig. 11) supplied.
Use the 4 screws supplied, with a tightening torque of 35 - 40 Nm, after protecting their thread with anti-seize prod
ucts.
The seal between burner and boiler must be airtight. After the start-up (see Ch. 5.3), check there is no leakage of flue
gases into the external environment.
Riello RS130/M Tc Industrial Natural Gas Burner for Heating

Recommend Products

Riello RS130/M Tc Industrial Natural Gas Burner for Heating
Riello RS130/M Tc Industrial Natural Gas Burner for Heating
Riello RS130/M Tc Industrial Natural Gas Burner for Heating

 

Riello RS130/M Tc Industrial Natural Gas Burner for HeatingRiello RS130/M Tc Industrial Natural Gas Burner for Heating

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now