  • Azbil C6097A0110 Gas Differential Pressure Switch for Measuring The Pressure for Industrial Burners & Boilers
  • Azbil C6097A0110 Gas Differential Pressure Switch for Measuring The Pressure for Industrial Burners & Boilers
  • Azbil C6097A0110 Gas Differential Pressure Switch for Measuring The Pressure for Industrial Burners & Boilers
  • Azbil C6097A0110 Gas Differential Pressure Switch for Measuring The Pressure for Industrial Burners & Boilers
  • Azbil C6097A0110 Gas Differential Pressure Switch for Measuring The Pressure for Industrial Burners & Boilers
  • Azbil C6097A0110 Gas Differential Pressure Switch for Measuring The Pressure for Industrial Burners & Boilers
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Recommend Products
Overview

Basic Info.

Model NO.
C6097A0110
Structure
Power Built-in Type
Usage
Control Switch, Playback Switch, Change-over Switch, Gas Burners Industrial Accessories
Explosion-proof Type
IP 54
Contact
Normally Close
Contact Type
Type a Contact
Detection Method
Retro-reflective Mode
Brand
Azbil
Certification
CE, CCC
Name
Pressure Switch
Model
C6097A0110
Max. Voltage
250V
Weight
2kg
Max. Working Pressure
20kpa
Voltage Rating
250V 5A 50/60 Hz
Degree of Protection
IP 54
Setting Range
0.1-1kpa
Output
Spdt Contact Output
After Warranty Service
Video Technical Support
Application/Usage
Gas Burners Industrial Accessories
Transport Package
Carton Box Packing
Specification
10X9X8 cm
Trademark
Azbil
Origin
Japan
HS Code
8481100090
Production Capacity
1000

Product Description

Azbil C6097A0110 Gas Differential Pressure Switch  For Measuring The Pressure of Gas Or Air Supplied To A Gas Burner

Product Description

 
Azbil C6097A0110 Gas Differential Pressure Switch for Measuring The Pressure for Industrial Burners & Boilers
Specification:
C6097A is a special pressure for city gas, natural gas, liquefied petroleum gas and air Detector. Can be widely used to measure the pressure of gas or air supplied to gas combustion devices Upper and lower limits, burner blower interlock, filter clogging detection, etc.
Features
1.Light weight and small size.
2.It can be installed vertically or horizontally. For details, refer to the installation posture in 6. Specifications.
3.Can be used for differential pressure and negative pressure. (for air only)
4.Simple pressure setting, transparent cover with strong visibility.
 
Azbil C6097A0110 Gas Differential Pressure Switch for Measuring The Pressure for Industrial Burners & Boilers
Overhaul:
In installation, maintenance, replacement of C6097A, etc., please perform the following inspections. Please consider the machine type, setting environment, frequency of use, etc. Determine the maintenance period. C6097A NO load side
Maintenance content · There is no abnormality in the pressure set point (the setting of the dial is not misaligned) · The transparent cover is not damaged · No abnormality in the installation of the exhaust pipe · No leakage in gas piping · No loose wiring
 
Azbil C6097A0110 Gas Differential Pressure Switch for Measuring The Pressure for Industrial Burners & Boilers
Installation:
Can be mounted horizontally or vertically with the dial indicator.
1. Please select the horizontal or vertical installation
posture.
2.Please use screw pliers or screwdriver to clamp the high-voltage side interface RP1/4 parallel 2 sides, install piping.There are 2 high-voltage side ports, side and bottom. install When assembling the tube to the high-pressure side port on the side,replace the plug to the bottom the high-voltage side interface. Also, after replacing the plug, be sure to confirm that there is no leakage.
3. When using flammable gas, connect the exhaust pipe to the low-pressure side port RP1/8.


Azbil C6097A0110 Gas Differential Pressure Switch for Measuring The Pressure for Industrial Burners & Boilers
PRODUCT SPECIFICATIONS
Model
C6097A0110
Supply Voltage
AC250V 50/60HZ
Setting Range
0.1-1Kpa
Usage
gas burner accessories

Detailed Photos

Azbil C6097A0110 Gas Differential Pressure Switch  For Measuring The Pressure of Gas Or Air Supplied To A Gas Burner

Recommend Products

 

Azbil C6097A0110 Gas Differential Pressure Switch for Measuring The Pressure for Industrial Burners & Boilers
Azbil C6097A0110 Gas Differential Pressure Switch for Measuring The Pressure for Industrial Burners & Boilers
Azbil C6097A0110 Gas Differential Pressure Switch for Measuring The Pressure for Industrial Burners & Boilers
Azbil C6097A0110 Gas Differential Pressure Switch for Measuring The Pressure for Industrial Burners & Boilers
Azbil C6097A0110 Gas Differential Pressure Switch for Measuring The Pressure for Industrial Burners & Boilers
Azbil C6097A0110 Gas Differential Pressure Switch for Measuring The Pressure for Industrial Burners & Boilers

 

Azbil C6097A0110 Gas Differential Pressure Switch for Measuring The Pressure for Industrial Burners & BoilersAzbil C6097A0110 Gas Differential Pressure Switch for Measuring The Pressure for Industrial Burners & Boilers

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier