Industrial Gas Gasifier ZPEX-100 Floor Type Explosion-proof Gas Gasifier 15KW For Burner Application
Product Overview
Model
|
Ex-100kg
|
Gross Weight
|
about 115kg
|
Power
|
15KW
|
Gasification
|
100kg/h
|
Working Pressure
|
1.76MPa
|
Overview:
Ex-series Zhongbanghao explosion-proof gasifier (also known as gasifier) is in accordance with GB3836.1-2000 (Electrical Equipment for Explosive Gas Environment Part 1: General Requirements), GB3836.2-2000 (Contracted Bank Gas Environment Use Part 2 of electrical equipment: flameproof type "d") regulations made into flameproof structure, its explosion-proof mark ExdIIBT4, suitable for the factory exists or may exist IIA, IIB, group T1-T3 flammable gases, vapors and air It is used for gasification in explosive hazard zone 1 or 2 places formed by mixing. The product has passed the inspection of the National Explosion-proof Electrical Product Quality Supervision and Inspection Center and obtained the explosion-proof certificate, the number is CNExx02.602X. The gasifier can work reliably in the following environments: a. The ambient temperature is -20ºC--+40ºC; b The altitude does not exceed 1000m; c The relative temperature of the surrounding air is not more than 90% (when the ambient temperature is 25°C); d There is no obvious shock and vibration; g Part of the gasifier heating pipe is well ventilated; f Place the gasifier in a well-ventilated place; Zhongbanghao explosion-proof gasifier is mainly suitable for gas supply systems in industrial factories, mines, residential quarters, and gas (gasified liquefied petroleum gas) supply systems in the catering industry and large-scale greenhouse heating industries.
FEATURES AT A GLANCE
Model and main technical parameters 1. Gasifier model and meaning of explosion-proof mark: ZPEx100/150 meaning: ZP - enterprise self-number Ex -- Explosion-proof type mark 100/150-Gasification capacity: 100kg/h or 150kg/h ExdIIBT4 Ex -- Explosion-proof mark explosion-proof type IIB - Factory Class II Class B Temperature group: <135ºC
Industrial Gas Gasifier ZPEX-100 Floor Type Explosion-proof Gas Gasifier 15KW For Burner Application
Structure Description:
1. The shell of the gasifier explosion-proof box is welded with Q235A steel plate. 2. The appearance and size of the gasifier are shown in the actual sample or sample drawing. 3. There are terminals in the explosion-proof box of the gasifier. 4. The gasifier is equipped with internal and external grounding bolts, and there is a grounding mark "Lu one 5. The gasifier is equipped with a water tank, coils and heaters. The principle is that the liquefied gas passes through the coils immersed in warm water, absorbs the heat of the warm water, vaporizes and overheats, and enters the pipe network, and the heat of the warm water is heated by electricity. The water temperature is controlled by the temperature controller at 55 ºC-70 ºC. There is a float switch on the gasifier with a low waterproof level. When the water level is lower than a certain height, the power supply can be automatically cut off to prevent the heater from drying out. Automatically cut off the current to prevent the temperature from being too high.
Wall-mounted: ZPEx wall-mounted circuit principle Zhongbanghao ZPEx wall-mounted gasifier, the electrical components are installed in the explosion-proof wiring compartment of the furnace body, turn on the power switch, and the furnace body starts to heat. The electronic thermostat automatically adjusts the water temperature of 60-70 °C: the anti-liquid floating ball valve can be used because the gasifier stops working due to electrical appliances and other reasons. to safety protection.
Installation And Use: 1. Inspection before installation of gasifier The following inspections should be carried out before installation of the gasifier a Whether the nameplate has explosion-proof mark, "Ex" mark, explosion-proof certificate number; b Open the explosion-proof box of the gasifier to check whether there is any debris or dust inside, and clean it up; c Whether there are internal and external grounding bolts and signs; d all parts are damaged or missing; e Gasifiers that have been transported for a long time or have been left unused for a long time must be measured before use The insulation resistance value between the terminal and the shell should not be less than 20M, otherwise it should be dried.
Industrial Gas Gasifier ZPEX-100 Floor Type Explosion-proof Gas Gasifier 15KW For Burner Application
Installation And Use:
Before installation and use, understand clearly the functions of each function marked on the furnace body: Safety valve: When the pressure in the furnace is too high and exceeds the specified gas pressure, it will automatically leak exhaust. Gas-phase pressure gauge: Displays the coil pressure in the furnace. Liquid phase inlet: the liquefied gas cylinder group or the liquid tank pipe is connected to the furnace body. Gas phase outlet: The outlet of the liquefied petroleum gas from liquid to gas, that is, it is directly connected to the user's pipeline when the gasifier is installed. Water injection port: the place where water is added to the furnace body. Water level gauge: Displays the water level in the furnace, that is, the water level that must be maintained in the furnace. Heater: The parts that work directly in the furnace body are directly connected to the power supply. Solenoid valve: It is a control valve that automatically prevents the liquid phase from flowing out, that is, when the liquid in the furnace body is not turned into gas, the phase outlet is automatically closed to prevent the liquid phase from flowing out. (Some furnaces do not have this equipment and replace this function with a float valve) Thermometer: The temperature display table in the furnace body, from which the working state can also be seen.