• Honeywel Complexity Ec7890b1028 Original Relay Modules Program Controller for Burners Parts Boilers & Boiler Accessories
  • Honeywel Complexity Ec7890b1028 Original Relay Modules Program Controller for Burners Parts Boilers & Boiler Accessories
  • Honeywel Complexity Ec7890b1028 Original Relay Modules Program Controller for Burners Parts Boilers & Boiler Accessories
  • Honeywel Complexity Ec7890b1028 Original Relay Modules Program Controller for Burners Parts Boilers & Boiler Accessories
  • Honeywel Complexity Ec7890b1028 Original Relay Modules Program Controller for Burners Parts Boilers & Boiler Accessories
  • Honeywel Complexity Ec7890b1028 Original Relay Modules Program Controller for Burners Parts Boilers & Boiler Accessories

Honeywel Complexity Ec7890b1028 Original Relay Modules Program Controller for Burners Parts Boilers & Boiler Accessories

Usage: Hydrogen, Nitrogen, Ng and LPG
Purpose: Control Gas
Parts: Burner Controller
Application Fields: Industrial Gas Burner
Noise Level: Low
Machine Size: Medium
Samples:
US$ 412/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
  • Overview
  • Product Description
  • Detailed Photos
  • Recommend Products
Overview

Basic Info.

Model NO.
EC7890B1028
Condition
New
Certification
ISO, CE
Name
Burner Controller
Model
Ec7890b1028
Brand
Honeywell
Power Supply
220-240 VAC (+10, -15%) 50/60 Hz.
Ambient Temperature
-40 C to +60 ° C.
Weight
Less 2kg
Color
Blue
Fusing
15A Maximum
Humidity
85% Relative Humidity Continuous, Noncondensing.
Vibration
0.5g Environment
After Warranty Service
Video Technical Support
Maximum Total Connected Load
2000 Va
Application/Usage
Gas Burners Industrial Accessories
Transport Package
Carton
Specification
19*19*15cm
Trademark
Honeywell
Origin
America
HS Code
8302600000
Production Capacity
1000

Product Description

Honeywel Complexity EC7890B1028 Original Relay Modules Program Controller For Burners Parts

Product Description

Application:
The Honeywell EC/RM7823A Relay Module is a microprocessor based flame detector relay that can be fitted with any 7800 SERIES Flame Amplifier to provide relay action from one dpdt relay when flame is or is not present. The EC/RM7823A system consists of a relay module, wiring subbase and flame amplifier.
Options include keyboard display module (KDM), personal computer interface, Data ControlBus Moduleô, remote display mounting and Combustion System Managerô Software.

PRODUCT SPECIFICATIONS
item
value
Condition
New
Warranty
1.5 years
Applicable Industries
Manufacturing Plant, Food & Beverage Factory, Farms, Restaurant, Construction works , Energy & Mining, Advertising Company
Weight (KG)
2
Showroom Location
None
Video outgoing-inspection
Provided
Machinery Test Report
Provided
Place of Origin
USA
Brand Name
Honeywell
Type
Gas Burner
Product name
Honeywel Complexity EC7890B1028 Original Relay Modules Program Controller
Brand
Honeywell
Model
EC7890B1028
Color
Blue
Power supply
220-240 Vac (+10, -15%) 50/60 Hz.
Maximum Total Connected Load
2000 VA
Ambient Temperature
Operating: -40°F to +140°F (-40°C to +60°C)
Humidity
85% relative humidity continuous, noncondensing.
Vibration
0.5G environment
Application/Usage
Gas Burners Industrial Accessories

Detailed Photos

Honeywel Complexity EC7890B1028 Original Relay Modules Program Controller For Burners Parts
Functions:
Functions provided by the EC/RM7823A include flame
monitoring, self-diagnostics and troubleshooting.The
EC/RM7823A is a solid state replacement for the R7023B,C
Flame Detector Relays.
The EC7823/RM7823 is a flame detector relay only. A
switchable primary control must be used to provide safe-start
check, safety lockout, load switching and other functions
required in Flame Safeguard systems
.
 

IMPORTANT:1. Wiring connections for the relay modules are unique; refer to Fig. 2 or the correct Specifications for proper subbase wiring.
2. Wiring must comply with all applicable codes, ordinances and regulations.
3. Wiring must comply with NEC Class 1 (Line Voltage) wiring.
4. Loads connected to the EC/RM7823A must not exceed those listed on the EC/RM7823A label or the
Specifications; see Table 3 or 4.
5. All external timers must be listed or component-recognized by authorities who have
proper jurisdiction.
6. For on-off gas-fired systems, some authorities who have jurisdiction prohibit the wiring of any limit or
operating contacts in series between the flame safeguard control and the main fuel valve(s).
7. Two flame detectors can be connected in parallel with the exception of Infrared Flame Detectors
(C7015).
8. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used
in accordance with the instructions, can cause interference with radio communications. It has been
tested and found to comply with the limits for a Class B computing device of Part 15 of FCC rules which
are designed to provide reasonable protection against such interference when operated in a commercial environment. Operation of this equipment in a residential area may cause interference; in which case, the users at their own expense may be required to take whatever measures are required to correct this interference.
9. This digital apparatus does not exceed the Class B limits for radio noise for digital apparatus set out in
the Radio Interference Regulations of the Canadian Department of Communications.

Honeywel Complexity Ec7890b1028 Original Relay Modules Program Controller for Burners Parts Boilers & Boiler Accessories
Honeywel Complexity Ec7890b1028 Original Relay Modules Program Controller for Burners Parts Boilers & Boiler Accessories
Honeywel Complexity Ec7890b1028 Original Relay Modules Program Controller for Burners Parts Boilers & Boiler Accessories




 

Recommend Products

 

Honeywel Complexity Ec7890b1028 Original Relay Modules Program Controller for Burners Parts Boilers & Boiler Accessories
Honeywel Complexity Ec7890b1028 Original Relay Modules Program Controller for Burners Parts Boilers & Boiler Accessories
Honeywel Complexity Ec7890b1028 Original Relay Modules Program Controller for Burners Parts Boilers & Boiler Accessories
Honeywel Complexity Ec7890b1028 Original Relay Modules Program Controller for Burners Parts Boilers & Boiler Accessories
Honeywel Complexity Ec7890b1028 Original Relay Modules Program Controller for Burners Parts Boilers & Boiler Accessories
Honeywel Complexity Ec7890b1028 Original Relay Modules Program Controller for Burners Parts Boilers & Boiler Accessories

 

Honeywell Burner Control RM7840L1018 Industrial Combustion System Controller Safety Program Controller
Honeywel Complexity Ec7890b1028 Original Relay Modules Program Controller for Burners Parts Boilers & Boiler AccessoriesHoneywel Complexity Ec7890b1028 Original Relay Modules Program Controller for Burners Parts Boilers & Boiler Accessories

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now