Usage: Hydrogen, Nitrogen
Purpose: Control Gas
Parts: Burner Controller
Application Fields: Industrial Gas Burner
Noise Level: Low
Machine Size: Small
Samples:
US$ 16/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
  • Overview
  • Product Description
  • Detailed Photos
  • Recommend Products
Overview

Basic Info.

Model NO.
LOA24.171B27
Condition
New
Certification
ISO, CE
Name
Burner Controller
Model
Loa24.171b27
Brand
Jate
Power Supply
220-240V 50/60 Hz.
Weight
Less 1kg
Color
Black
Tsamax
10s
After Warranty Service
Video Technical Support
Application/Usage
Gas Burners Industrial Accessories
Shipping Term
DHL/UPS/FedEx/TNT
Delivery Time
Payment After About 2 Day
Transport Package
Carton
Specification
11*8*7cm
Trademark
JATE
Origin
China
HS Code
8302600000
Production Capacity
1000

Product Description

JATE Sequence Controller LOA24.171B27 Mechanical Gas Combustion Program Controller Offer Wholesale Price

Product Description

Use, features:
Use:The LOA... are used for the startup, supervision and control of 1- or 2-stage forced draft oil burners in intermittent operation.
Yellow-burning flames are supervised with photoresistive detectors QRB..., blueburning flames with blue-flame detectors QRC...
General features: - Forced draft oil burners conforming to EN 267
- Oil atomization burners in monoblock design conforming to EN 230: 1991
- Undervoltage detection
- Bridging contact for oil preheater (not with LOA28.173A27)
General features - Special versions including models for incinerator plants and flash-steam generators
- LOA36... with color display of flame intensity and operating

PRODUCT SPECIFICATIONS
item
value
Condition
New
Warranty
1.5 years
Applicable Industries
Manufacturing Plant, Food & Beverage Factory, Farms, Restaurant, Construction works , Energy & Mining, Advertising Company
Weight (KG)
Less 1kg
Showroom Location
None
Video outgoing-inspection
Provided
Machinery Test Report
Provided
Place of Origin
China
Brand Name
JATE
Type
Gas Burner
Product name
LOA24.171B27 Mechanical Gas Combustion Program Controller
Brand
JATE
Model
LOA24.171B27
Color
Black
Power supply
220-240V 50/60 Hz.
Power consumption approx. AC 3.5 VA
TSAmax 10s
Application/Usage
Gas Burners Industrial Accessories

Detailed Photos

JATE Sequence Controller LOA24.171B27 Mechanical Gas Combustion Program Controller Offer Wholesale Price
Jate Sequence Controller Loa24.171b27 Mechanical Gas Combustion Program Controller Offer Wholesale Price
Installation notes:
1.Always run high-voltage ignition cables separately while observing the greatest
possible distance to the unit and to other cables
2.Do not mix up live and neutral conductors
Install switches, fuses, earthing, etc., in compliance with local regulations
3.Ensure that the maximum permissible amperages will not be exceeded (see Tech
nical data)

 
 
Jate Sequence Controller Loa24.171b27 Mechanical Gas Combustion Program Controller Offer Wholesale Price

Electrical connection of flame detectors:

It is important to achieve practically disturbance- and loss-free signal transmission:
1.Never run the detector cable together with other cables
- Line capacitance reduces the magnitude of the flame signal
- Use a separate cable
2. Observe the permissible lengths of the flame detector cables (see Data Sheets
N7714 (QRB...) and N7716 (QRC...))
3.Earth the burner in compliance with the relevant regulations; earthing the boiler
alone does not suffice

 

Jate Sequence Controller Loa24.171b27 Mechanical Gas Combustion Program Controller Offer Wholesale Price
Warning notes:
To avoid injury to persons, damage to property or the environment, the following warning notes must be observed!
Do not open, interfere with or modify the unit!
1. All activities (mounting, installation and service work, etc.) must be performed by qualified staff
2.Before making any wiring changes in the connection area, completely isolate the plant from mains supply (all-polar disconnection). Ensure that the plant cannot be inadvertently switched on again and that it is indeed dead. If not observed, there is a risk of electric shock hazard
3. Ensure protection against electric shock hazard by providing adequate protection for the burner control's connection terminals. If not observed, there will be a risk of electric shock
4. Each time work has been carried out (mounting, installation, service work, etc.), check to ensure that wiring is in an orderly state and make the safety checks as indicated in Commissioning notes above
5.Press the lockout reset button / operating button only manually (applying a force of no more than 60 N), without using any tools or pointed objects. If not observed, the safety functions are no longer ensured and there will be a risk of electric shock
6.Fall or shock can adversely affect the safety functions. Such units must not be put into operation, even if they do not exhibit any damage. If not observed, the safety functions are no longer ensured and there will be a risk of electric shock
Mounting notes Ensure that the relevant national safety regulations are complied with.


Jate Sequence Controller Loa24.171b27 Mechanical Gas Combustion Program Controller Offer Wholesale Price

 

Recommend Products

 

Jate Sequence Controller Loa24.171b27 Mechanical Gas Combustion Program Controller Offer Wholesale Price
Jate Sequence Controller Loa24.171b27 Mechanical Gas Combustion Program Controller Offer Wholesale Price
Jate Sequence Controller Loa24.171b27 Mechanical Gas Combustion Program Controller Offer Wholesale Price
 
Jate Sequence Controller Loa24.171b27 Mechanical Gas Combustion Program Controller Offer Wholesale Price
Jate Sequence Controller Loa24.171b27 Mechanical Gas Combustion Program Controller Offer Wholesale Price
Jate Sequence Controller Loa24.171b27 Mechanical Gas Combustion Program Controller Offer Wholesale Price

 

JATE Sequence Controller LOA24.171B27 Mechanical Gas Combustion Program Controller Offer Wholesale Price
Jate Sequence Controller Loa24.171b27 Mechanical Gas Combustion Program Controller Offer Wholesale PriceJate Sequence Controller Loa24.171b27 Mechanical Gas Combustion Program Controller Offer Wholesale Price

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now