Rl 64 T. C Dual Stage Induatrial Light Oil Burners for Boiler System

Product Details
Customization: Available
Certification: CE
Customized: Non-Customized
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW PayPal
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company
Secured Trading Service
Gold Member Since 2023

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
40
Year of Establishment
2009-08-20
  • Rl 64 T. C Dual Stage Induatrial Light Oil Burners for Boiler System
  • Rl 64 T. C Dual Stage Induatrial Light Oil Burners for Boiler System
  • Rl 64 T. C Dual Stage Induatrial Light Oil Burners for Boiler System
  • Rl 64 T. C Dual Stage Induatrial Light Oil Burners for Boiler System
  • Rl 64 T. C Dual Stage Induatrial Light Oil Burners for Boiler System
  • Rl 64 T. C Dual Stage Induatrial Light Oil Burners for Boiler System
Find Similar Products
  • Overview
  • Product Description
  • Company Profile
Overview

Basic Info.

Model NO.
RL 64 T. C
Surface Treatment
Painted
Fuel
Oil
Range of Applications
Industrial
Type
Burner
Application
Boiler System
Output Power
206/391-830 Kw
Material
Metal
Brand
Rie Llo
Voltage
230 V
Transport Package
Wooden Box Packing
Specification
50kg
Trademark
Rie Llo
Origin
Italy

Packaging & Delivery

Package Size
90.00cm * 58.00cm * 55.00cm
Package Gross Weight
50.000kg

Product Description

Product Description
Rl 64 T. C Dual Stage Induatrial Light Oil Burners for Boiler System
RL SERIES 
    The RL series of burners covers a firing range from 154 to 2700 kW, and it has been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers. 
    Operation is "two stage"; the burners are fitted with a microprocessor-based control panel, which supplies indication of burner status and fault causes. Optimisation of sound emissions is guaranteed by the special design of the air suction circuit and by incorporated sound proofing material. The elevated performance of the fans and combustion head, guarantee flexibility of use and excellent working at all firing rates. 
    The exclusive design ensures reduced dimensions, simple use and maintenance. A wide range of accessories guarantees elevated working flexibility.
Rl 64 T. C Dual Stage Induatrial Light Oil Burners for Boiler System
Rl 64 T. C Dual Stage Induatrial Light Oil Burners for Boiler System
Rl 64 T. C Dual Stage Induatrial Light Oil Burners for Boiler System
STATE OF SUPPLY
RL 50 - 64 MZ - 70 - 100 - 130 - 190 - 250 MZ models 
Monoblock forced draught oil burner with two stage operation, fully automatic, made up of: 
- Air suction circuit lined with sound-proofing material 
- Fan with reverse curve blades (RL 50 - 70 - 100 - 130 models) or straight blades (RL 64 MZ - 190 - 250 MZ models) 
- Air damper for air setting controlled by an adjustable hydraulic ram (or by a servomotor for the RL 250 MZ) 
- Starting motor at 2800 rpm, three-phase 400V with neutral, 50Hz 
- Combustion head, that can be set on the basis of required output, fitted with: 
              - stainless steel end cone, resistant to corrosion and high temperatures 
              - ignition electrodes 
              - flame stability disk 
- Gears pump for high pressure fuel supply, fitted with: 
              - filter 
              - pressure regulator 
              - connections for installing a pressure gauge and vacuometer 
              - internal by-pass for single pipe installation 
- Valve unit with an oil safety valve and two delivery oil valves on the output circuit 
- Photocell for flame detection 
- Microprocessor-based burner safety control box, with diagnostic function 
- Burner on/off switch 
- Flame inspection window 
- 1st - 2nd stage manual switch 
- Slide bars for easier installation and maintenance 
- Protection filter against radio interference 
- IP 44 electric protection level. 
Standard equipment: 
- 2 flexible pipes for connection to the oil supply network 
- 2 gaskets for the flexible pipes 
- 2 nipples for connection to the pump 
- 4 screws for fixing the burner flange to the boiler 
- 1 thermal screen 
- Fairleads for electrical connections (RL 50 models) 
- 2 slide bar extensions (for the extended head models and the RL 190 - 250 MZ models) 
- Instruction handbook for installation, use and maintenance 
- Spare parts catalogue.
Company Profile
Rl 64 T. C Dual Stage Induatrial Light Oil Burners for Boiler System
Rl 64 T. C Dual Stage Induatrial Light Oil Burners for Boiler System
Rl 64 T. C Dual Stage Induatrial Light Oil Burners for Boiler System
Rl 64 T. C Dual Stage Induatrial Light Oil Burners for Boiler System
Rl 64 T. C Dual Stage Induatrial Light Oil Burners for Boiler System
Rl 64 T. C Dual Stage Induatrial Light Oil Burners for Boiler System

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now