Azbil Gas Burner Controller R4750b208 for Industrial Combustion Safety Detector

Product Details
Customization: Available
Certification: CE, ISO
Customized: Non-Customized
Still deciding? Get samples of US$ 105/Piece
Request Sample
Manufacturer/Factory & Trading Company
Gold Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
40
Year of Establishment
2009-08-20
  • Azbil Gas Burner Controller R4750b208 for Industrial Combustion Safety Detector
  • Azbil Gas Burner Controller R4750b208 for Industrial Combustion Safety Detector
  • Azbil Gas Burner Controller R4750b208 for Industrial Combustion Safety Detector
  • Azbil Gas Burner Controller R4750b208 for Industrial Combustion Safety Detector
  • Azbil Gas Burner Controller R4750b208 for Industrial Combustion Safety Detector
  • Azbil Gas Burner Controller R4750b208 for Industrial Combustion Safety Detector
Find Similar Products

Basic Info.

Model NO.
R4750B208
Surface Treatment
Natural
Fuel
Gas
Range of Applications
Industrial
Type
Burner Controller
Name
Azbil Burner Controller
Model
R4750b208
Deliver Time
2~15days
Term of Payment
EXW/Fob
Use
Gas Burner Accessories
Transport Package
Carton
Specification
91(W)*104(H)*123(L)mm
Trademark
Azbil
Origin
Japan
HS Code
8302600000
Production Capacity
1000

Product Description

Azbil Gas Burner Controller R4750b208 For Industrial Combustion Safety Detector

OVERVIEW
   The R4750B is a combustion safety controller for medium sized gas combustion units to control heating. For combustion units up to 580KW/h, it provides automatic ignition control and control of combustion units Safety monitoring. The structural design and component reliability of the product ensure the operation of the combustion device the order is correct.
PRODUCT PARAMETERS
Name Burner Controller
Brand Azbil
Model R4750B208
Origin Japan
Deliver Time 2~15 days
Consumed Power 7W+25% MAX
Temperature Range -20~+60ºC
RH 90%RH 40ºC
Weight 0.68KG
 
Azbil Gas Burner Controller R4750b208 for Industrial Combustion Safety Detector
Features At a Glance

 
1,Combustion status is displayed with LED light in FLAME/ALARM.
2,The ground network detection circuit is designed to ensure the safety of the power supply polarity when the ground network occurs such as the valve or the ignition transformer.
3,The startup safety circuit with fault protection is adopted, so when there is an internal and external loop failure, suspected flame signal, etc., it will not be started.
4,When ignition failure (no fire), abnormal fire break and other locked occasions, the use of manual reset can only be restarted after the structure.
 

 

WARNING

1,Do not install it in the following places
(1)Places where special drugs or corrosive gases are present (e.g. ammonia, sulfur, hydrochloric acid, ethylene compounds, etc.)
(2)Places where water drops or is too wet.
(3) High temperature places.
(4) A place where the vibration lasts for a long time.
2, Please connect according to the specified basis.
3, In order to prevent electric shock and meter damage, please connect the power supply last. Misunderstanding that touching other subterminals can cause accidents and damage to the meter.
4,The load of each terminal connection should not exceed the rated value.
5,Please use the power supply with the same voltage and frequency as indicated by the machine.
6,For timers and auxiliary relays used as additional functions, please select reliable products and correctly form loops according to your needs.
7,Please ground according to the standard above D type grounding specified in the electrical equipment technical standard, and be sure to ground the burner body.
8,Do not tie the power cord and the high-voltage cable of the ignition transformer with the wire of the flame monitoring rod, and do not put it in the same wire tube, please wire separately.In particular, the high-voltage cable should be distributed separately, 10 cm away from the burner controller Above.
9,Please connect the ignition transformer high-voltage cable reliably to ensure that there is no bad contact. Poor contact will produce high frequency waves, radio noise, etc., causing misoperation. In addition, install the ignition transformer directly with the burner body or the metal part electrically connected to the burner body.
10,After connecting cables, ensure that the cables are correctly connected. Incorrect wiring may damage the unit or cause incorrect actions.


RECOMMEND PRODUCTS
Azbil Gas Burner Controller R4750b208 for Industrial Combustion Safety Detector
Azbil Gas Burner Controller R4750b208 for Industrial Combustion Safety Detector
Azbil Gas Burner Controller R4750b208 for Industrial Combustion Safety Detector

ABOUT US
https://yhg688.en.made-in-china.com/company-Shenzhen-YHG-Heating-Science-Technology-Co-ltd.html
Azbil Gas Burner Controller R4750b208 for Industrial Combustion Safety DetectorAzbil Gas Burner Controller R4750b208 for Industrial Combustion Safety DetectorAzbil Gas Burner Controller R4750b208 for Industrial Combustion Safety DetectorAzbil Gas Burner Controller R4750b208 for Industrial Combustion Safety DetectorAzbil Gas Burner Controller R4750b208 for Industrial Combustion Safety DetectorAzbil Gas Burner Controller R4750b208 for Industrial Combustion Safety DetectorAzbil Gas Burner Controller R4750b208 for Industrial Combustion Safety Detector

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier