Germany Siemens or High Stability Lfl1.333 Burner Manufacturer Price Offer Controller Program Controller
|
Still deciding? Get samples of $ !
Request Sample
|
Product Details
| Customization: | Available |
|---|---|
| Application Fields: | Industrial Gas Burner |
| Certification: | ISO, CE |
Gold Member Since 2023
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Year of Establishment
2009-08-20
Number of Employees
40
Find Similar Products
Basic Info.
- Model NO.
- LFL1.333
- Condition
- New
- Noise Level
- Low
- Parts
- Burner Controller
- Purpose
- Control Gas
- Name
- Burner Controller
- Model
- Lfl1.333
- Brand
- Siemens
- Power Supply
- 220-240V 50/60 Hz.
- Power Consumption
- Approx. AC 3.5 Va
- Ambient Temperature
- -20...+60 °c
- Weight
- Less 2kg
- Color
- Black
- Primary Fuse (External)
- Max. 10 a (Slow)
- Humidity
- < 95 % R.H
- Degree of Protection
- IP 40, with The Exception of The Connection Area
- After Warranty Service
- Video Technical Support
- Application/Usage
- Gas Burners Industrial Accessories
- Usage
- Hydrogen, Nitrogen, Ng and LPG
- Machine Size
- Medium
- Transport Package
- Carton
- Specification
- 12*12*11cm
- Trademark
- Siemens
- Origin
- Germany
- HS Code
- 8302600000
- Production Capacity
- 1000
Product Description
Germany Siemens OR High Stability LFL1.333 Burner Manufacturer Price Offer Controller Program Controller
PRODUCT SPECIFICATIONS
Germany Siemens OR High Stability LFL1.333 Burner Manufacturer Price Offer Controller Program Controller

Mechanical structure:
The combustion control device is a plug-in housing and base of shock and heat resistant black plastic Self-locking indicator, fault light and reset button are located under the window of the unit.
The unit is equipped with a replaceable safety Fuses and Spare Fuses
The unit is equipped with a replaceable safety Fuses and Spare Fuses
PRODUCT SPECIFICATIONS
|
item
|
value
|
|
Condition
|
New
|
|
Warranty
|
1.5 years
|
|
Applicable Industries
|
Manufacturing Plant, Food & Beverage Factory, Farms, Restaurant, Construction works , Energy & Mining, Advertising Company
|
|
Weight (KG)
|
2
|
|
Showroom Location
|
None
|
|
Video outgoing-inspection
|
Provided
|
|
Machinery Test Report
|
Provided
|
|
Place of Origin
|
Germany
|
|
Brand Name
|
Siemens
|
|
Type
|
Gas Burner
|
|
Product name
|
Germany Siemens OR High Stability LFL1.333 Burner Manufacturer Price Offer Controller Program Controller |
|
Brand
|
Siemens |
|
Model
|
LFL1.333 |
|
Color
|
Black
|
|
Power supply
|
220-240V 50/60 Hz. |
| Power consumption | approx. AC 3.5 VA |
|
Ambient Temperature
|
-20...+60 °C |
|
Humidity
|
< 95 % r.h. |
| Degree of protection | IP 40, with the exception of the connection area |
|
Application/Usage
|
Gas Burners Industrial Accessories
|
Use:
LFL1…Burner Controls Designed for Forced Air Burner Control and Monitoring Available for Direct Ignition or Medium to high power burner with pilot burner Universal for oil and gas and can be used for stationary preheating air Burner WLE according to DIN 4794 The difference between the 01 series and the 02 series is the safety time of the ignition burner with the ignition gas valve LFL1.638 is selected for the controller of high-power atmospheric combustion If the burner requires continuous operation control
Function:
Standard The following features of LFL… provide a high level of security - Monitoring and light tests are started immediately after the burner time has elapsed, meaning when the fuel valve is open or When the valve is not closed, it will self-lock immediately after this time has elapsed. The test is the purge time before the next burner start-up. Terminate after - The flame monitoring circuit automatically monitors each burner start-up - Monitor fuel release control contactor for sticking during post-purging - Built-in fuse protects the contactor from overload
Burner Control
-This unit allows the burner with or without post-purge - The current of the fan motor is less than 4A, the maximum starting current is 20A, and it can be directly connected - Separate control of output damper actuator on/off and min. - Monitor damper control to ensure rated air flow during pre-purge Check start position closed or minimum low load position open at the beginning and after the end of the pre-purge time the minimum position is in execution When the actuator does not actuate the damper to the predetermined position, the burner start-up procedure will be aborted - Air pressure monitoring before start-up, air pressure monitoring function test during pre-purge until controlled shutdown - Separate ignition fuel valve control output shuts off after 2nd safety time - 2 fuel release control outputs with 3rd stage control output or load control if necessary - Simple measures to increase safety time from 2.5 seconds to 5 seconds when Series 1 Programmer Direct Ignition See Engineering Notes Provides longer safety time to accommodate local safety regulations - When load control is activated, the control output of the damper actuator is independent of other control section circuits - Connection of remote reset device Remote reset and remote emergency shutdown
-This unit allows the burner with or without post-purge - The current of the fan motor is less than 4A, the maximum starting current is 20A, and it can be directly connected - Separate control of output damper actuator on/off and min. - Monitor damper control to ensure rated air flow during pre-purge Check start position closed or minimum low load position open at the beginning and after the end of the pre-purge time the minimum position is in execution When the actuator does not actuate the damper to the predetermined position, the burner start-up procedure will be aborted - Air pressure monitoring before start-up, air pressure monitoring function test during pre-purge until controlled shutdown - Separate ignition fuel valve control output shuts off after 2nd safety time - 2 fuel release control outputs with 3rd stage control output or load control if necessary - Simple measures to increase safety time from 2.5 seconds to 5 seconds when Series 1 Programmer Direct Ignition See Engineering Notes Provides longer safety time to accommodate local safety regulations - When load control is activated, the control output of the damper actuator is independent of other control section circuits - Connection of remote reset device Remote reset and remote emergency shutdown
Germany Siemens OR High Stability LFL1.333 Burner Manufacturer Price Offer Controller Program Controller

Send your message to this supplier
People who viewed this also viewed
Product Groups
More
Find Similar Products By Category
- Supplier Homepage
- Products
- Siemens Accessories
- Controller
- Germany Siemens or High Stability Lfl1.333 Burner Manufacturer Price Offer Controller Program Controller
Hot Searches
More