• New Siemens Lgk16.335A27 Burner Controller for Gas Burner Accessories
  • New Siemens Lgk16.335A27 Burner Controller for Gas Burner Accessories
  • New Siemens Lgk16.335A27 Burner Controller for Gas Burner Accessories
  • New Siemens Lgk16.335A27 Burner Controller for Gas Burner Accessories
  • New Siemens Lgk16.335A27 Burner Controller for Gas Burner Accessories
  • New Siemens Lgk16.335A27 Burner Controller for Gas Burner Accessories

New Siemens Lgk16.335A27 Burner Controller for Gas Burner Accessories

Usage: Hydrogen, Nitrogen, Ng and LPG
Purpose: Control Gas
Parts: Burner Controller
Application Fields: Industrial Gas Burner
Noise Level: Low
Machine Size: Medium
Samples:
US$ 794.62/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
  • Overview
  • Product Description
  • Detailed Photos
Overview

Basic Info.

Model NO.
LGK16.335A27
Condition
New
Certification
ISO, CE
Name
Burner Controller
Model
Lgk16.335A27
Brand
Siemens
Power Supply
230V 50/60 Hz.
Power Consumption
Approx. AC 3.5 Va
Ambient Temperature
-20...+60 °c
Weight
Less 2kg
Color
Black
TV
37s
Humidity
< 95 % R.H
Degree of Protection
IP 40, with The Exception of The Connection Area
After Warranty Service
Video Technical Support
Application/Usage
Gas Burners Industrial Accessories
Transport Package
Carton
Specification
12*12*11cm
Trademark
Siemens
Origin
Germany
HS Code
8302600000
Production Capacity
1000

Product Description

New Siemens LGK16.335A27 Burner Controller For Gas Burner Accessories

Product Description

Circuit Connections for Flame Detectors:
It is important to achieve almost interference-free and loss-free signal transmission:
• Detector conduit must not be installed with other conductors - Conduit capacitance reduces the magnitude of the flame signal - please use a separate cable
• Please note the permissible length of the detector tube, see "Technical Data"
• Do not connect 2 flame detectors QRA53... / QRA55... in parallel
• When connecting QRA53... / QRA55..., terminal 22 must be grounded
Danger of touching ionizing flame detectors
• The ignition electrode and the ionizing flame detector should be installed so that the ignition spark does not affect the ionizing flame detector (electrical flame detector). danger of gas overload) and avoid ignition sparks affecting the ionization monitoring device
• Monitoring can use ionization flame detectors and flame detectors QRA..., but not both for technical safety reasons With two flame detectors, except for the 2nd safety time «t9». At the end of the 2nd safety time, the detection The flame must be extinguished, for example by disconnecting the ignition valve at terminal 17
 

PRODUCT SPECIFICATIONS
item
value
Condition
New
Warranty
1.5 years
Applicable Industries
Manufacturing Plant, Food & Beverage Factory, Farms, Restaurant, Construction works , Energy & Mining, Advertising Company
Weight (KG)
2
Showroom Location
None
Video outgoing-inspection
Provided
Machinery Test Report
Provided
Place of Origin
Germany
Brand Name
Siemens
Type
Gas Burner
Product name
New Siemens LGK16.335A27 Burner Controller For Gas Burner Accessories
Brand
Siemens
Model
LGK16.335A27
Color
Black
Power supply
230V 50/60 Hz.
Power consumption approx. AC 3.5 VA
Ambient Temperature
-20...+60 °C
Humidity
< 95 % r.h.
Degree of protection  IP 40, with the exception of  the connection area
Application/Usage
Gas Burners Industrial Accessories

Detailed Photos

New Siemens LGK16.335A27 Burner Controller For Gas Burner Accessories
New Siemens Lgk16.335A27 Burner Controller for Gas Burner Accessories
Use:
 
Automatic Burner
• Gas, oil or dual fuel vented burners for medium and large power
• Flame signal amplifier with self-test function
• Multi-stage or adjustable medium to large burners for continuous operation
• With air pressure detection and monitorable air valve control
 
LOK16... / LGK16... and this data sheet are intended for use in products with original equipment of LOK16... / LGK16... Manufacturer (OEM) use!

 
 
New Siemens Lgk16.335A27 Burner Controller for Gas Burner Accessories

Applications:

The automatic burner is equipped with a self-checking flame monitoring circuit. The automatic burner can not only cause the flame signal to advance or disappear, but also can cause the flame signal during the operation of the burner. False flame detectors, detector conduits and flame signal amplifiers provide the necessary safety measures in the event of damage. Controllers are available in various provisions for self-testing flame monitoring systems or suitable oil and gas combustion equipment: - Continuously running burners - Intermittently operating burners for continuous operation for more than 24 hours at high heat loads, e.g. with boiler follow-up control system burner in the system - Burners falling within the scope of the Technical Regulations for Steam Furnaces (Federal Republic of Germany TRD 411 and 412) - In-plant burners that need to be monitored by a self-checking flame monitoring system due to special safety requirements - The control program and controller connection circuit are the same as LAL2... and LFL1... (except LFL1.148), so that the existing The device can also be equipped with a self-test controller

 

New Siemens Lgk16.335A27 Burner Controller for Gas Burner Accessories
Service Life
The controller is designed for a service life
 of 250,000 burner start cycles, which equates to approximately 10 during normal heating operation Service life in years (from the date of manufacture stated on the nameplate). The calculation of the service life is based on the standard EN230 / Endurance tests according to EN298 and a list of related test bases published by the European Component Manufacturers Associatio . The design life of an automatic burner is as specified in the data sheet. Reach design life (number of burner cycles or time), the automatic burner must be replaced by authorized personnel. * The designed service life is not the warranty period specified in the delivery terms.
Installation Notes:
• High voltage ignition cables should be routed separately and at the greatest possible distance from equipment and other cables
• Neutrals must not be connected interchangeably
• Install switches, fuses and ground wires in accordance with local regulations in force
• The maximum permissible current load of the connection terminals must not be exceeded



New Siemens Lgk16.335A27 Burner Controller for Gas Burner Accessories

 

 

New Siemens Lgk16.335A27 Burner Controller for Gas Burner Accessories
New Siemens Lgk16.335A27 Burner Controller for Gas Burner Accessories
New Siemens Lgk16.335A27 Burner Controller for Gas Burner Accessories
 
New Siemens Lgk16.335A27 Burner Controller for Gas Burner Accessories
New Siemens Lgk16.335A27 Burner Controller for Gas Burner Accessories
New Siemens Lgk16.335A27 Burner Controller for Gas Burner Accessories

 

New Siemens LGK16.335A27 Burner Controller For Gas Burner Accessories
New Siemens Lgk16.335A27 Burner Controller for Gas Burner AccessoriesNew Siemens Lgk16.335A27 Burner Controller for Gas Burner Accessories

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now