Lme11.330c2 Control Box Replacement Siemens Gas Burner Control Valve Controller Burner Spares

Product Details
Customization: Available
Application Fields: Industrial Gas Burner
Certification: ISO, CE
Still deciding? Get samples of US$ 98/Piece
Request Sample
Manufacturer/Factory & Trading Company
Gold Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
40
Year of Establishment
2009-08-20
  • Lme11.330c2 Control Box Replacement Siemens Gas Burner Control Valve Controller Burner Spares
  • Lme11.330c2 Control Box Replacement Siemens Gas Burner Control Valve Controller Burner Spares
  • Lme11.330c2 Control Box Replacement Siemens Gas Burner Control Valve Controller Burner Spares
  • Lme11.330c2 Control Box Replacement Siemens Gas Burner Control Valve Controller Burner Spares
  • Lme11.330c2 Control Box Replacement Siemens Gas Burner Control Valve Controller Burner Spares
  • Lme11.330c2 Control Box Replacement Siemens Gas Burner Control Valve Controller Burner Spares
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Recommend Products
Overview

Basic Info.

Model NO.
LME11.330C2
Condition
New
Noise Level
Low
Parts
Valve, Burner Controller
Purpose
Control Gas
Name
Burner Controller
Model
Lme11.330c2
Brand
Siemens
Power Supply
230V 50/60 Hz.
Power Consumption
Approx. AC 3.5 Va
Ambient Temperature
-20...+60 °c
Weight
Less 2kg
Color
Black
Primary Fuse (External)
Max. 10 a (Slow)
Humidity
< 95 % R.H
After Warranty Service
Video Technical Support
Application/Usage
Gas Burners Industrial Accessories
Usage
Hydrogen, Nitrogen, Ng and LPG
Machine Size
Medium
Transport Package
Carton
Specification
11*8*7cm
Trademark
Siemens
Origin
Germany
HS Code
8302600000
Production Capacity
1000

Product Description

LME11.330C2 Control Box Replacement  Siemens Burner Controller Burner Spares

Product Description

Application:
LME...for monitoring and control of single-stage or double-stage gas burners during start-up and intermittent operation. flame monitoring Pass ionization bar or flame detector QRA and auxiliary equipment AGQ3 or use blue flame detector QRC. according to the shell Dimensions, LME... Same burner controller as LGB and LMG

PRODUCT SPECIFICATIONS
item
value
Condition
New
Warranty
1.5 years
Applicable Industries
Manufacturing Plant, Food & Beverage Factory, Farms, Restaurant, Construction works , Energy & Mining, Advertising Company
Weight (KG)
Less 1kg
Showroom Location
None
Video outgoing-inspection
Provided
Machinery Test Report
Provided
Place of Origin
Germany
Brand Name
Siemens
Type
Gas Burner
Product name
LME11.330C2 Control Box Replacement  Siemens Burner Controller
Brand
Siemens
Model
LME11.330C2
Color
Black
Power supply
230V 50/60 Hz.
Power consumption approx. AC 3.5 VA
Ambient Temperature
-20...+60 °C
Humidity
< 95 % r.h.
Degree of protection  IP 40, with the exception of  the connection area
Application/Usage
Gas Burners Industrial Accessories

Detailed Photos

LME11.330C2 Control Box Replacement  GSiemens Burner Controller Burner Spares
Lme11.330c2 Control Box Replacement Siemens Gas Burner Control Valve Controller Burner Spares
Features:
Combustion control according to EN 298 Strong exhaust burner according to EN 676 Undervoltage detection Monitor air pressure during startup and operation with an air pressure switch Convenient remote reset Various colors display information on error status and operating status A limited number of repetitions Precise control sequence due to the use of digital signal processing After 24 hours of continuous operation, it must be stopped once

 
 
Lme11.330c2 Control Box Replacement Siemens Gas Burner Control Valve Controller Burner Spares
Installation Precautions:
The controller unit and other cables must be installed separately from the high voltage ignition cables.
Do not confuse phase and neutral.
Install switches, fuses, grounding, etc. in accordance with local regulations.
Connection diagram showing the application of a grounded neutral wire to the burner control. Ionization current monitoring in the network without connection In the case of a ground conductor, terminal 2 must be routed through an RC unit (Type: ARC 4 668 9066 0). Connect the ground wire. Local regulations must be followed (e.g. protection against electric shock) Because the mains voltage of AC 230 V / 50 Hz produces a current leakage of up to 2.7 mA.
Verify that the maximum amount of current allowed by the terminal is not exceeded.
Do not supply an external mains voltage to the control output of the combustion controller, when the test unit controls the combustion controller (fuel valve, etc.), LME do not connect.
In the absence of a fan, the AGK25 must be connected to terminal 3, otherwise the burner will not start reliably.
  For safety, connect the neutral conductor to terminal 2. As shown below, the burner components (fan, ignition compressor, air valve) must be connected to the neutral conductor. The connection between the neutral conductor and terminal 2 is at the control unit The bottom is pre-wired.

 

Lme11.330c2 Control Box Replacement Siemens Gas Burner Control Valve Controller Burner Spares
Electrical installation of flame detectors:
To exclude interference, it is important to avoid losses in signal transmission:
1.Do not install the detector wires together with other wires - Line capacitance reduces the level of the flame signal - Use a separate cable
2.Check the maximum permissible length of the detector wiring (refer to the «Technical Manual»)
3.The ionization bar is not protected against the risk of electric shock
4.Locate and confirm the location of the ignition electrode and ionization probe so that the ignition spark does not pass over the ionization rod (danger of electrical overload) and checks that affect ionization
5.Insulation resistance - Minimum resistance between ion bar and ground is 50 M- Contaminated detector mounts reduce insulation resistance, thereby supporting creep currents The wiring of the burner should comply with the relevant regulations; grounding the boiler alone is not sufficient

Flame Monitoring
The principle of flame monitoring a Flame detector with ionization rod with or without ground wire Interfering with the monitoring circuit for a stable flame Can cause false fires if there is a short circuit between the detector and the burner flame signal b with UV flame detector QRA…series Oil or gas burners see instruction manual 7712 c If using both ionizing rod flame detectors and UV flame detectors (eg with ignition burners or gas, electronic ignition oil burners)

Lme11.330c2 Control Box Replacement Siemens Gas Burner Control Valve Controller Burner Spares

 

Recommend Products

 

Lme11.330c2 Control Box Replacement Siemens Gas Burner Control Valve Controller Burner Spares
Lme11.330c2 Control Box Replacement Siemens Gas Burner Control Valve Controller Burner Spares
Lme11.330c2 Control Box Replacement Siemens Gas Burner Control Valve Controller Burner Spares
 
Lme11.330c2 Control Box Replacement Siemens Gas Burner Control Valve Controller Burner Spares
Lme11.330c2 Control Box Replacement Siemens Gas Burner Control Valve Controller Burner Spares
Lme11.330c2 Control Box Replacement Siemens Gas Burner Control Valve Controller Burner Spares

 

LME11.330C2 Control Box Replacement  Siemens Burner Controller Burner Spares
Lme11.330c2 Control Box Replacement Siemens Gas Burner Control Valve Controller Burner SparesLme11.330c2 Control Box Replacement Siemens Gas Burner Control Valve Controller Burner Spares

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier