Jate Qra4. U Integrated UV Flame Detector Electric Eye Burner Flame Detector for Burner Parts

Usage: Hydrogen, Nitrogen, Ng and LPG
Purpose: Control Gas
Parts: Flame Detector
Application Fields: Industrial Gas Burner
Noise Level: Ultra Quiet
Machine Size: Small
Samples:
US$ 57/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
QRA4. U
Condition
New
Certification
ISO, CE
Model
Qra4.U
Brand
Siemens
Name
Flame Detector
Material
Metal
Color
Gold and Black
Deliver Time
2-3 Days
Term of Payment
EXW/Fob
Use
Gas Burner Accessories
After Warranty Service
Video Technical Support
Function
Detect Ultraviolet
Transport Package
Carton
Specification
15*11*6CM
Trademark
JATE
Origin
China
HS Code
8403900000
Production Capacity
2000

Product Description

JATE QRA4.U Integrated UV flame detector Electric Eye Burner Flame Detector For Burner Parts
 
Detector Basic Data
Average UV unit life
approx. 10´000 hours at max. +50 °C; higher The ambient temperature reduces the corresponding life of the unit
 
Protection class
IP 54(Install must confirm it)
 
Installation location
Optional
 
Weight
about 180g
 
Allowable combustion chamber pressure
Max 150 mbar
Environmental Conditions
Shipping
IEC 721-3-2
 
Climatic Conditions
class 2K3
 
Mechanical Condition
class 2M2
 
Temperature Range
-20...+60 °C
 
Humidity
< 95 % r.h.
 
Run
IEC 721-3-3
 
Climatic Conditions
class 3K5
 
Mechanical Condition
class 3M5
 
Temperature Range
-20...+60 °C
 
Humidity
< 95 % r.h.

Jate Qra4. U Integrated UV Flame Detector Electric Eye Burner Flame Detector for Burner Parts

Summary:

Flame detectors are used with combustion controllers from Siemens Building Technologies for monitoring of gas and oil flames.
The QRA4.U flame detector is especially suitable for OEMs integrating it into their products.
Use: Flame detectors are used to monitor gas flames, yellow or blue fuel combustion flames, and calibration of ignition sparks.
JATE QRA4.U Integrated UV flame detector Electric Eye Burner Flame Detector For Burner Parts
 
Jate Qra4. U Integrated UV Flame Detector Electric Eye Burner Flame Detector for Burner Parts
Service Precautions
• Before replacing the flame detector, make sure that the wiring is properly connected. • KF8832 service pack is for short-term use only
Jate Qra4. U Integrated UV Flame Detector Electric Eye Burner Flame Detector for Burner Parts
Warning notice To avoid personal injury, property damage and environmental damage, the following warning notices must be observed! Do not open, interfere with or modify the flame detector! • All activities (installation, assembly and service work, etc.) are to be carried out by professionals • Fully isolate the equipment from mains (all two stages disconnected) before making any wiring changes in the detector's connection area. • Provide adequate protection to connection terminals from electrical shock. • Check to make sure the wiring is properly connected. • Halogen lamps, welding equipment, special lamps, or ignition sparks may generate enough radiation to cause the detector's UV Unit is lit. X-rays and gamma rays can also cause false flame signals. • A fall or impact can affect the safety function. Such detector units do not work, even though they appear to be No damage at all. Installation Precautions • Ensure compliance with relevant national security rules Installation Guide • Controller unit and other cables must be installed separately from high voltage ignition cables Electrical connections for flame detectors To exclude interference, it is important to avoid losses in signal transmission: • Do not run detector cables with other cables - Line capacitance reduces the level of the flame signal - Use a separate cable • Observe the permissible length of the detector cable (refer to Technical Data)

JATE QRA4.U Integrated UV flame detector Electric Eye Burner Flame Detector For Burner Parts
 
Jate Qra4. U Integrated UV Flame Detector Electric Eye Burner Flame Detector for Burner Parts

Jate Qra4. U Integrated UV Flame Detector Electric Eye Burner Flame Detector for Burner Parts

Jate Qra4. U Integrated UV Flame Detector Electric Eye Burner Flame Detector for Burner Parts
Jate Qra4. U Integrated UV Flame Detector Electric Eye Burner Flame Detector for Burner Parts
Jate Qra4. U Integrated UV Flame Detector Electric Eye Burner Flame Detector for Burner Parts

 

Jate Qra4. U Integrated UV Flame Detector Electric Eye Burner Flame Detector for Burner PartsJate Qra4. U Integrated UV Flame Detector Electric Eye Burner Flame Detector for Burner Parts

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now