Kromschroder Flame Detector UVS10D1G1 for Industrial Gas Burner
Description
High sensitivity, unaffected by sunlight, infrared and bulb light sources Can prevent short circuit of flame monitoring signal cable UVS10 can replace previous models Rugged Design Meets Industrial Needs For use with automatic burner controllers from ElsterKromshroder, EN298 compliant Flame monitoring for monitoring gas burners, burner control units and automatic burner controllers for hot air stoves, gas boilers, industrial furnaces and ElsterKromshrode
Model
|
UVS10D1G1 |
Brand
|
Kromschroder |
Name |
Kromschroder Flame Detector |
Usage
|
Gas burner accessories
|
Use:
The ultraviolet flame monitor is used for intermittent working conditions, and is used to monitor the flame monitoring of direct ignition burners or main burners with ignition burners. UVS1, UVS6 and UVS8 can be replaced by UVS10 series
FEATURES:
Maintenance cycle: The life of the UV photosensitive tube: 10000 hours After this period, the photosensitive tube must be replaced. alternative model UVS1 alternative model UVS10D4G1 UVS6 alternative number UVS10D0G1 UVS8 alternative model UVS10D2
Technical parameters:
Thermal protector integrated in aluminum housing with terminal blocks Distance between UV flame detector and flame: 300mm-400mm UV photosensitive tube: P578, Spectral range: 190-270nm, Maximum sensitivity: 210m±10nm Minimum flame signal: 1μA Protection level: IP65 Ambient temperature: -40-80ºC