• Honeywell Ve4040A1243 T Gas Proportional Solenoid Valves The Electromagnetic Valve
  • Honeywell Ve4040A1243 T Gas Proportional Solenoid Valves The Electromagnetic Valve
  • Honeywell Ve4040A1243 T Gas Proportional Solenoid Valves The Electromagnetic Valve
  • Honeywell Ve4040A1243 T Gas Proportional Solenoid Valves The Electromagnetic Valve
  • Honeywell Ve4040A1243 T Gas Proportional Solenoid Valves The Electromagnetic Valve
  • Honeywell Ve4040A1243 T Gas Proportional Solenoid Valves The Electromagnetic Valve

Honeywell Ve4040A1243 T Gas Proportional Solenoid Valves The Electromagnetic Valve

Certification: CE, ISO
Customized: Non-Customized
Surface Treatment: Natural
Fuel: Gas
Range of Applications: Industrial
Type: Solenoid Valve
Samples:
US$ 220/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
VE4040A1243 T
Name
Honeywell Solenoid Valve
Deliver Time
2~15days
Term of Payment
EXW/Fob
Use
Gas Burner Accessories
Model
Ve4040A1243 T
Transport Package
Carton
Specification
195(W)*135(H)*130(L)mm
Trademark
Honeywell
Origin
America
HS Code
8302600000
Production Capacity
1000

Product Description

Honeywell VE4040A1243 T Solenoid Air Valves Gas Proportional Control Valve


OVERVIEW
    Honeywell UGV class solenoid valves can be used for fuel supply control of various gas burners. Solenoid valve from DN10 to DN100 (1/2" ~ 4"); Including fast opening and fast closing, slow opening and fast closing; Flow regulation; Threaded or flanged connection; A variety of types such as normally off and normally on are available.
PRODUCT PARAMETERS
Name Solenoid Valve
Brand Honeywell
Model VE4040A1243 T
Origin America
Deliver Time 2~15 days
IP Grade IP65
Temperature Range -15ºC ...+60ºC
Usage gas burner accessories
Valve Body brass body for 1/4" version, aluminium body for others.
  
Honeywell Ve4040A1243 T Gas Proportional Solenoid Valves The Electromagnetic Valve
Features At a Glance
 
Product Features
* For pilot and small burner applications in gas power burners, gas boilers, ovens, furnaces and other gas consuming appliances.
* Gas valve type: AC powered, non regulated ON/OFF normally closed, fast opening.
* Media: natural gas, propane, air.
* Materials: brass body for 1/4" version, aluminium body for others.
* Approvals: CE (EN161), GOST, AGA
* Pipe connection: Internal thread as per ISO 7/1 (Rp)
* Threads type: BSP
* Maximum opening time: 1s
* Maximum closing time: 1s
* Ambient temperature: -15...60C
* Protection class: IP65
* Electrical connection: DIN plug
* 220...240 Vac versions
* Valve dimension: Rp 1/2
* Max. operating pressure: 200mbar
* Shipping Weight: 7 kg
 


RECOMMEND PRODUCTS
Honeywell Ve4040A1243 T Gas Proportional Solenoid Valves The Electromagnetic Valve
Honeywell Ve4040A1243 T Gas Proportional Solenoid Valves The Electromagnetic Valve
Honeywell Ve4040A1243 T Gas Proportional Solenoid Valves The Electromagnetic Valve
 

WARNING

1,Do not install it in the following places
(1)Places where special drugs or corrosive gases are present (e.g. ammonia, sulfur, hydrochloric acid, ethylene compounds, etc.)
(2)Places where water drops or is too wet.
(3) High temperature places.
(4) A place where the vibration lasts for a long time.
2, Please connect according to the specified basis.
3, In order to prevent electric shock and meter damage, please connect the power supply last. Misunderstanding that touching other subterminals can cause accidents and damage to the meter.
4,The load of each terminal connection should not exceed the rated value.
5,Please use the power supply with the same voltage and frequency as indicated by the machine.
6,For timers and auxiliary relays used as additional functions, please select reliable products and correctly form loops according to your needs.
7,Please ground according to the standard above D type grounding specified in the electrical equipment technical standard, and be sure to ground the burner body.
8,Do not tie the power cord and the high-voltage cable of the ignition transformer with the wire of the flame monitoring rod, and do not put it in the same wire tube, please wire separately.In particular, the high-voltage cable should be distributed separately, 10 cm away from the burner controller Above.
9,Please connect the ignition transformer high-voltage cable reliably to ensure that there is no bad contact. Poor contact will produce high frequency waves, radio noise, etc., causing misoperation. In addition, install the ignition transformer directly with the burner body or the metal part electrically connected to the burner body.
10,After connecting cables, ensure that the cables are correctly connected. Incorrect wiring may damage the unit or cause incorrect actions.


ABOUT US
https://yhg688.en.made-in-china.com/company-Shenzhen-YHG-Heating-Science-Technology-Co-ltd.html
Honeywell Ve4040A1243 T Gas Proportional Solenoid Valves The Electromagnetic ValveHoneywell Ve4040A1243 T Gas Proportional Solenoid Valves The Electromagnetic ValveHoneywell Ve4040A1243 T Gas Proportional Solenoid Valves The Electromagnetic ValveHoneywell Ve4040A1243 T Gas Proportional Solenoid Valves The Electromagnetic ValveHoneywell Ve4040A1243 T Gas Proportional Solenoid Valves The Electromagnetic ValveHoneywell Ve4040A1243 T Gas Proportional Solenoid Valves The Electromagnetic ValveHoneywell Ve4040A1243 T Gas Proportional Solenoid Valves The Electromagnetic Valve

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now